search
Twitter Rss Feeds
MicrosoftArticlesForumsGroups
C# .NET
VB.NET
Visual Studio .NET
ADO.NET
Xml/Xslt
VB 6.0
.NET CF
GDI+
LINQ
Deployment
Security
FoxPro
Silverlight / WPF
Entity Framework
RIA Services

Web ProgrammingArticlesForumsGroups
JavaScript
ASP
ASP.NET
Web Services

Non-MicrosoftArticlesForumsGroups
NHibernate
Perl
PHP
Ruby
Java
Linux / Unix
Apple
Open Source

DatabasesArticlesForumsGroups
SQL Server
Access
Oracle
MySQL
Other Databases

OfficeArticlesForumsGroups
Microsoft Excel
Microsoft Word
Microsoft Powerpoint
Publisher
Money

Operating SystemsArticlesForumsGroups
Windows 7
Windows Server
Windows Vista
Windows XP
Windows Update
MAC
Linux / UNIX

Server PlatformsArticlesForumsGroups
Share Point
BizTalk
Site Server
Exhange Server
IIS
Transaction Server

Graphic DesignArticlesForumsGroups
Macromedia Flash
Adobe PhotoShop
Microsoft Expression

OtherArticlesForumsGroups
Subversion / CVS
Ask Dr. Dotnetsky
Active Directory
Networking
Uninstall Virus
Job Openings
Reviews
Search Engines
Resumes

 

cXML error in pipeline
I am using the Orders cXML schema created from test data and I am 
 
running into this error on validating the cXML schema.  I get the 
 
following error: 
 
"For security reasons DTD is prohibited in this XML document. To enable 
 
DTD processing set the ProhibitDtd property on XmlReaderSettings to 
 
false and pass the settings into XmlReader.Create method" 
 
does anyone know how to fix this error. 
 
Thanks,
Read Entire Conversation

rastreadores GPS Ratreador gps localizadores bloqueadores 7082168
CENTRAL ÚNICA DE VENDAS 
 
10 Marcas de ratreadores, Compare e Compre. 
 
Rastreador de Veículo 
 
Rastreadores de Veículos 
 
Rastreador GPS 
 
Rastreadores GPS 
 
Rastreador Ituran 
 
Rastreadores Ituran 
 
Rastreador Portátil 
 
Rastreadores Portáteis. 
 
Assistência 24 Horas 
 
Visite agora mesmo nosso site. 
 
http://tel011-50523122.vila.bol.com.br/ 
 
Graber - Teletrim - Tele Trim - Ituran - 
 
Rastreadores gps , Localizadores, Bloqueadores 
 
Graber - Teletrim - Tele Trim - Ituran - 
 
Ra ...
Read Entire Conversation

Sending an Email with two body parts using SMTP

Read Entire Conversation

Web Service Response inside Atomic Scope.
I am using the following code: 
 
Code: 
 
RcvPipeOutput = 
 
Microsoft.XLANGs.Pipeline.XLANGPipelineManager.ExecuteReceivePipeline(typeof(BizTalkFromWipToAC.SQLParseReceivePipeline), OutputInterchange); 
 
This recquires that it is run inside an atomic scope. So all my logic 
 
afterwards, the loop of the records and message assignments and the sending 
 
to the web service are occuring in the atomic scope. 
 
The web service was changed to provide a response. Atomic scope does not 
 
allow rec ...
Read Entire Conversation

:ns0 namespace issue
Hi 
 
This must be simple, but I am having a trying time figuring it out. 
 
My output of the schema I generate from Biztalk generate instance 
 
always adds a :ns0 in the begining and end of the message. 
 
Hence my receive port is not able to validate that schema, since it is 
 
not expecting that ns0 namespace. 
 
My question is how do I eliminate the ns0 namespace. Basically I mean 
 
it should not expect ns0. 
 
Any help is appreeciated.. 
 
Here is the sample schema 
 
<ns0:Message vers ...
Read Entire Conversation

HTTP Adapter strange error in Ochestration
Hi All, 
 
Every once in a while (that's as accurate as I can describe it) we see an 
 
error in the event log indicating: 
 
The adapter failed to transmit message 
 
going to send port "sendPortName" with URL 
 
"http://10.10.10.10:9999/webapp/Servlet". 
 
It will be retransmitted after the retry interval specified for this 
 
Send Port. 
 
Details:"Cannot access a disposed object. Object 
 
name: 'System.Net.Sockets.NetworkStream'.". 
 
Has anyone ever seen this issue?  It appears "random"... ...
Read Entire Conversation

using ports from within nested orchestrations
Hi, 
 
I am working on a prototype for a quite complex BizTalk Solution. I would 
 
like to use nested orchestrations. There are two issues: 
 
The B2B scenario supplied with BizTalk Server 2006 is using ports from 
 
within nested orchestrations without supplying them via orchestration 
 
parameters. When I try to do this likewise in my solution it will not work. 
 
No error appears but no message gets delivered, too. 
 
My question is: How can I use ports from within a nested orchestration 
 
 ...
Read Entire Conversation

Mapping results of a web service
First post/new user, so hope this isn't too elementary... 
 
I have a web service that takes a parameter and is returning a dataset 
 
from a SQL database. The service is running correctly, now I would like 
 
to call it from my BizTalk orchestration. I would like to map the 
 
results that are received from the web service into a particular XML 
 
schema which I have created a schema file for. Is it possible to create 
 
a map between a web service's return schema and another? When I go to 
 
c ...
Read Entire Conversation

Receive multiple types of messages in the same Receive port ?!
Hi, 
 
I have about 5 different messages that I would like to be able to receive 
 
them from the same receive port and inside the orchestration, I need to be 
 
able to map each one of them seperately and send them out to different send 
 
ports. 
 
It should be noted that some of the messages will be mapped using two 
 
different maps to create different messages for different purposes. 
 
What is the best way of doing so? 
 
Any help would highly be appreciated. Thank you. 
 
Kam
Read Entire Conversation

Generic Documents and Generic Mapping
http://geekswithblogs.net/bloesgen/ 
 
The site above talks about generic documents to biztalk and applying a 
 
generic mapping to the incoming document that would result in an output 
 
message which is not known at design time. 
 
Although seemingly very interesting I am not able to find anything 
 
online on how this is implemented or can be achieved in biztalk 2006. 
 
Would any of you give me some suggestions on this topic or a resource 
 
where I could find some more details on this topic, 
 
Thanks 
 
Sree
Read Entire Conversation

Generic Documents and Generic Mapping
http://geekswithblogs.net/bloesgen/ 
 
The site above talks about generic documents to biztalk and applying a 
 
generic mapping to the incoming document that would result in an output 
 
message which is not known at design time. 
 
Although seemingly very interesting I am not able to find anything 
 
online on how this is implemented or can be achieved in biztalk 2006. 
 
Would any of you give me some suggestions on this topic or a resource 
 
where I could find some more details on this topic, 
 
Thanks 
 
Sree
Read Entire Conversation

Importing BPEL Sample into Visual Studio 2005 Prof fails
When creating a new BPEL Import Project in VS 2005 Prof using the Biztalk 
 
BPEL Sample I always get the following error (translated into english from 
 
the german error message): 
 
Error: B1020: Internal error in the import component. 
 
More information: Calling a  COM-Component returned a HRESULT E_FAIL 
 
error. 
 
Error on Import.
Read Entire Conversation

BizTalk 2006 Orchestration Designer in VS 2005
For some reason my VS 2005 Orchestration Designer has lost its bindings 
 
and now defaults to the xml. Does anyone know what exe I must nagivate 
 
to to set up the proper Orchestration Designer? 
 
Thanks 
 
Gavin
Read Entire Conversation

Orchestration with two Activiations
hi,guys: 
 
I'm a guy to biztalk 2006. currently working on an OA workflow using 
 
Biztalk 2006. my orchestration has two receive port, one for an 
 
request(orchestration activiation) , other for an operator action 
 
result(infopath submit to Biztalk-WS). I wonder how to submit the result to 
 
the RIGHT orchestration which have the correct request?
Read Entire Conversation

Loop is skipping records
Ok.. I am using code to send items to a receive pipeline. 
 
I use a loop with this function in the loop: 
 
RcvPipeOutput.MoveNext() 
 
Then inside the loop I set the message with code as follows: 
 
FFMessage = null; 
 
RcvPipeOutput.GetCurrent(FFMessage); 
 
Then I send it to a web service to be put into a database. 
 
When running the orch it selects and sends every other record. So for 10 
 
records... I only get 5 into the database (and it is every other). I change 
 
the total count and i ...
Read Entire Conversation

Loops with XmlDocument
I have a loop shape constructed inside my orchestration.  Inside the 
 
loop is an expression block that I assign a XML document to a 
 
XmlDocument variable using LoadXml.  I know I must first execute: 
 
myVar = new System.Xml.XmlDocument(); 
 
But do I need to do this in each loop iteration or only outside the 
 
loop at the beginning?  I am seeing some large memory footprints and 
 
just want to make sure that I am not overlooking something with my 
 
usage of creating these .Net objects. 
 
Thanks 
 
Chris
Read Entire Conversation

Having trouble consuming a RPC web service Required part string was not found in the message
hi,i'm trying to consume an rpc/encoded web service using biztalk and SOAP 
 
as transport type. 
 
the orchestration goes smoothly but the passthrutransmit pipeline terminates 
 
with an error 
 
"Required part string was not found in the message". 
 
I am assuming that my request doesn't even reach the web service. From HAT, 
 
i can see that I populate the message part (there's only one message part 
 
and it is of type string). I was thinking that I'm missing out sending the 
 
method name,  ...
Read Entire Conversation

Retrieving ActionInstanceId
Hi 
 
I'm working with an HWS were I want to be able to "kill" another hws. The 
 
only info I have is that HWS:s ActivityFlowID. How can i retreive an 
 
ActionInstanceID from that?
Read Entire Conversation

Exposing Orchestration as Web Service
I have exposed a orchestration as web service and created a form in infopath 
 
as a client to use this exposed web service. It is working fine on the same 
 
PC. 
 
When I host this Web Service on other PC where Biztalk server is not 
 
installed and try to browse the web service in Internet Explorer it was 
 
working fine. But when I try to post the message through the Infopath form I 
 
am getting the "Internal SOAP Processing Faliure" error message. 
 
On the Machine on which Web service is  ...
Read Entire Conversation

XLANGPart.LoadFrom(stream) failing - UnauthorizedAccessException
Hi, 
 
I am trying to update an XLANGMessage in my custom component. I have an 
 
orchestration that receives message A. 
 
In a construct shape (declared as constructing message B), message A is then 
 
assigned to message B, and message B is passed from a message assignment 
 
shape into my component as a parameter to a method. 
 
My component then generates a PDF stream using Crystal Reports, and then 
 
attempts to load the XLANGMessage's 1st data part with the stream generated 
 
by Crystal ...
Read Entire Conversation

Envelop and SOAP Adapter
Hello! 
 
I have a pretty simple orchestration receiving XML input and output XML 
 
messages. The orch works great with FILE transport (both Receiver and Send 
 
Port). 
 
Challenge: when I tried to replace Receiver Port using SOAP transport, I no 
 
longer see the output message (dictated by Send port using FILE transport). 
 
Here is the particular error message I got: 
 
"The Messaging engine failed to process a message submitted by adapter:SOAP 
 
Source URL:/BizTalkWebService/WebService1.a ...
Read Entire Conversation

promotion with direct ports
Promoting values via a Expression work fine if the output goes to a 
 
static or dynamic port but how can I promote values when using Direct 
 
ports ?
Read Entire Conversation

Q: regarding control of monitor orch, worker orchs, and correlatio
I've been testing various messaging techniques in BizTalk 2006 and have hit a 
 
snag. 
 
Setup: 
 
-------- 
 
- a pipeline that is configured to process a batch message containing 1..n 
 
batch items and inject a "BatchReceived" message into the batch.  The 
 
pipeline promotes various context properties including a BatchId (might end 
 
up using the InterchangeId instead.) 
 
- a batch monitor orchestration that is used to perform authorization and 
 
monitoring of the batch completion proces ...
Read Entire Conversation

Visual Studio Just Closes Down
I am just learning about Biztalk 2006 with VS 2005 and have been going 
 
through the tutorials.  Odd thing just started happening.  I was about half 
 
way through creating an orchestration ( I was creating a send port) when I 
 
realized I had mis-spelled a port type.  I couldn't figure out how to rename 
 
it, so I deleted it and tried to recreate it.  VS gave me the error message 
 
stating I already had a port of that name.  I tried a few other things, like 
 
close down VS and re-open the  ...
Read Entire Conversation

Biztalk Orchestration Hangs yet shows Active
We have begun to experience an oddity behavior on my production biztalk 
 
server environment.  There have been no microsoft patches, no code 
 
changes, and no environmental changes performed that we can pin point 
 
or attribute the programs with. 
 
The biztalk environment is setup with an ODBC receive location that 
 
polls a database for data to be processed.  This poller starts an 
 
orchestration that invokes the necessary child orchestrations to 
 
process different document types based  ...
Read Entire Conversation