Can't set the connectivity options - Rya

19-Mar-07 06:23:05
Hi,
After I reinstalled the PB 5.0, there is a dialog said "Platform Builder was
unable to read the device settings from the Datastore.". I'd tried to remove
C:\Documents and Settings\account_name\Local Settings\Application
Data\Microsoft\CoreCon\1.0 from HDD but it is not work. Any advice? Thanks.

B.R.
Ryan
button
 
 

Can't set the connectivity options - Shane Tangen [MS]

19-Mar-07 09:20:11
Hello Ryan,

Please try the the following:



1) Shutdown all instances of PB (version 5.0 and later) and make sure
Cepb.exe, CeSvcHost.exe (CeSvcH~1.exe) and DeviceEmulator.exe are gone from
the task manager.



2) Back up the C:\Documents and Settings\<user>\local settings\application
data\microsoft\corecon folder



3) Purge that folder [This will destroy all previously configured device
settings. It is important to make a backup as in step 2 if you need to
retain the other device settings and revert back].

Then,



4) Back up C:\Documents and Settings\all users\application
data\microsoft\corecon\1.0\addons folder to something outside of



5) Purge that addons folder under the corecon\1.0



6) Create a new one by that name under the corecon\1.0 folder



7) Copy C:\Program Files\<PB Install folder>\CoreCon\SDK\XSL\Addons\*.xsl to
the new ...\coreCon\1.0\Addons folder you created.



8) Also copy C:\Program Files\<PB Install
folder>\CEPB\bin\microsoft.platformbuilder500.servicecategory.xsl to the
above addons folder.

9) Relaunch PB and try creating and configuring a new device.


--
Thanks,
Shane

shane.tangen@online.microsoft.com (remove "online" from reply-to address)
http://blogs.msdn.com/ce_base/
_____________________________________________________________
This posting is provided "AS IS" with no warranties, and confers no rights.
_____________________________________________________________
button
 

Can't set the connectivity options - Rya

19-Mar-07 10:39:02
Hi Shane,
Very thnak you. It is work. Thanks again.

B.R.
Ryan
button
 
IPSM and Clean Boot